DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

SSH EN 50065-2-2:2003

Specifikime për sinjalizimin në instalimet elektrike me tension të ulët në diapazonin e frekuencave 3 kHz deri 148.5 kHzPjesa 2 - 2: Kërkesa për imunitetin për aparatet dhe për sistemet e komunikimit në rrjetin elektrik. që punojnë në bandën e frekuencave

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 2-2: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments
24 dhj 2007

General information

60.60     24 dhj 2007

DPS

DPS/KT 3

European Norm

33.040.30  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

This standard applies to electrical equipment using signals in the frequency range 95 kHz to
148,5 kHz to transmit or receive information on low voltage electrical systems, in industrial
environments. In the case of equipment which includes functions other than the transmission or
reception of information on low voltage electrical supplies, this standard applies only to that part
of the equipment intended for such transmission or reception of information. Other parts of the
equipment shall comply with the immunity standard or standards relevant to the functions of those
other parts. In the event of tests being specified in those other standards of a different severity
and where the construction of the equipment is such that the functions cannot be tested
separately, the higher severity shall apply to all affected functions.
The object of this standard is to limit mutual influence between mains communication equipment
and systems (MCES) operating in different frequency bands as defined in EN 50065-1 and to
contribute to ensuring electromagnetic compatibility in general. It specifies essential immunity
requirements and test methods, including those tests which are to be performed during typetesting
of MCES on low-voltage installations, for electromagnetic interference in general and
more specific interference coming from other MCES. It therefore defines the immunity test
requirements for apparatus in relation to continuous and transient disturbances, both conducted
and radiated, and electrostatic discharges. Test requirements are specified for each port
considered.
This standard gives limits which are applicable to products operating in industrial environments.
The levels do not however cover extreme cases which may occur in any location but with a low
probability of occurrence. In special cases situations will arise where the level of disturbances
may exceed the levels specified in this standard e.g. where a hand-held transmitter is used in
proximity to an apparatus. In these instances special mitigation measures may have to be
employed.
It does not specify immunity between mains communication systems operating in the same band
(as defined in EN 50065-1) or immunity to signals originating from power line carrier systems
operating on high or medium voltage networks.

Related directives

Directives related to this standards.

2004/108/EC

Direktiva 2004/108/EC e Parlamentit Europian dhe e Këshillit e 15 dhjetor 2004 për përafrimin e ligjeve të Shteteve Anëtare në lidhje me përputhshmërinë elektromagnetike dhe shfuqizimin e Direktivës 89/336/EEC

Të harmonizuara
2014/30/EU

Direktiva e BE 2014/30 e Parlamentit Evropian dhe e Këshillit e datës 26 Shkurt 2014 mbi harmonizimin e ligjeve të Shteteve Anëtare në lidhje me përputhshmërinë elektromagnetike (riformulim)

Të harmonizuara

Life cycle

NOW

PUBLISHED
SSH EN 50065-2-2:2003
60.60 Standard published
24 dhj 2007

Related project

Adopted from EN 50065-2-2:2003

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login