SSH ENV 13381-2:2002

Metodat e provës për përcaktimin e kontributit në rezistencën ndaj zjarrit të elemetëve të konstruksionit - Pjesa 2: Membranat mbrojtëse vertikale

Test methods for determining the contribution to the fire resistance of stuctural members - Part 2: Vertical protective membranes
95.99 Withdrawal of Standard   23 mar 2015

General information

95.99     23 mar 2015

DPS

DPS/KT 114

Pre Standard

13.220.50     13.220.99  

Scope

This part of this European Prestandard specifies a test method for determining the ability of a vertical protective membrane, when used as a fire resistant barrier, to contribute to the fire resistance of loadbearing vertical structural building members fabricated from steel, concrete, steel / concrete composites or timber. The method described is applicable to any type of vertical protective membrane, which can be associated with a separate bracing membrane.

The vertical protective membrane can be separate from the structural building member and be self-supporting or can be attached to the structural building member and can form part of any load bearing structure. This test method is applicable to vertical protective membranes where there is a separating gap of at least 5 mm size between the vertical protective membrane and the structural building member, otherwise alternative test methods prENV 13381-3, prENV 13381-4, prENV 13381-6 or prENV 13381-7 should be used as appropriate

This test method and assessment is not applicable to the following:

a) all situations where the cavity behind the vertical protective membrane contains more than a specified amount of combustible materials, e.g. electrical cables and pipes, other than where timber structural members themselves are required;

b) all situations where the cavity is to be used as a service or ventilation shaft;

c) all situations where the vertical protective membrane acts as a bracing membrane.

This European Prestandard contains the fire test which specifies the tests which should be carried out whereby the vertical protective membrane together with the structural member to be protected is exposed to the specified fire. The fire exposure, to the standard temperature/time curve given in EN 1363-1, is applied to the side which would be exposed in practice.

The test method makes provision, through specified optional additional procedures, for the collection of data which can be used as direct

Related directives

Directives related to this standards.

89/106/EEC

Produkte ndërtimi

305/2011

Rregullorja (BE) Nr. 305/2011 e Parlamentit Evropian dhe e Këshillit e datës 9 Mars 2011 që parashtron kushtet e harmonizuara për tregtimin e produkteve të ndërtimit dhe shfuqizimin e Direktivës së Këshillit KEE/89/106

Life cycle

NOW

WITHDRAWN
SSH ENV 13381-2:2002
95.99 Withdrawal of Standard
23 mar 2015

REVISED BY

PUBLISHED
SSH EN 13381-2:2014

Related project

Adopted from ENV 13381-2:2002

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login