Shfuqizuar
This European Standard specifies methods for the identification and assessment of hazardous situations leading to explosion and the design and construction measures appropriate for the required safety. This is achieved by:
- risk assessment;
- risk reduction.
The safety of equipment, protective systems and components can be achieved by eliminating hazards and/or limiting the risk, i.e. by:
a) appropriate design (without using safeguarding);
b) safeguarding;
c) information for use;
d) any other preventive measures.
Measures in accordance with a) (prevention) and b) (protection) against explosions are dealt with in Clause 6, measures according to c) against explosions are dealt with in Clause 7. Measures in accordance with d) are not specified in this European Standard. They are dealt with in EN ISO 12100:2010, Clause 6.
The preventive and protective measures described in this European Standard will not provide the required level of safety unless the equipment, protective systems and components are operated within their intended use and are installed and maintained according to the relevant codes of practice or requirements.
This standard specifies general design and construction methods to help designers and manufacturers in achieving explosion safety in the design of equipment, protective systems and components.
This European Standard is applicable to any equipment, protective systems and components intended to be used in potentially explosive atmospheres, under atmospheric conditions. These atmospheres can arise from flammable materials processed, used or released by the equipment, protective systems and components or from materials in the vicinity of the equipment, protective systems and components and/or from the materials of construction of the equipment, protective systems and components.
This European Standard is applicable to equipment, protective systems and components at all stages of its use.
(....)
Directives related to this standards.
Pajisje dhe sisteme të mbrojtjes për përdorim në atmosfera potencialisht shpërthyese (ATEX)
Të harmonizuaraDirektiva 2006/42/EC e Parlamentit Europian dhe e Këshillit të 17 majit 2006 për makinerinë, dhe amendimi i Direktivës 95/16/EC (rinovim)
Të harmonizuaraDirectve 2008/68/EC e Parlamentit Europian dhe e Këshillit e 24 shtator 2008 e transportit të brendëshëm të mallrave të rrezikshme
Direktiva e BE 2014/34 e Parlamentit Europian dhe e Këshillit e datës 26 Shkurt 2014 mbi harmonizimin e ligjeve të Shteteve Anëtare në lidhje me pajisjet dhe sistemet mbrojtëse të destinuara për përdorim në atmosfera potencialisht shpërthyese (riformulim)
Të harmonizuara
WITHDRAWN
SSH EN 1127-1:2011
95.99
Withdrawal of Standard
23 korr 2020
PUBLISHED
SSH EN 1127-1:2019