DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

ISO 7919-2:2009

Mechanical vibration — Evaluation of machine vibration by measurements on rotating shafts — Part 2: Land-based steam turbines and generators in excess of 50 MW with normal operating speeds of 1 500 r/min, 1 800 r/min, 3 000 r/min and 3 600 r/min
30 sht 2009
95.99 Withdrawal of Standard   27 korr 2017

General information

95.99     27 korr 2017

ISO

ISO/TC 108/SC 2

International Standard

17.160     29.160.40     27.040  

anglisht   frëngjisht  

Buying

Shfuqizuar

Language in which you want to receive the document.

Scope

ISO 7919-2:2009 establishes provisions for applying evaluation criteria for the severity of in-situ, broad-band shaft vibration measured radial (i.e. transverse) to the shaft axis at, or close to, the main bearings. These are in terms of:
- vibration under normal steady-state operating conditions;
- vibration during other (non-steady-state) conditions when transient changes are taking place, including run up or run down, initial loading and load changes;
- changes in vibration which can occur during normal steady-state operation.
ISO 7919-2:2009 is applicable to land-based steam turbines and generators with power outputs greater than 50 MW and a normal operating speed of 1 500 r/min, 1800 r/min, 3 000 r/min or 3 600 r/min.

Life cycle

PREVIOUSLY

WITHDRAWN
ISO 7919-2:2001

NOW

WITHDRAWN
ISO 7919-2:2009
95.99 Withdrawal of Standard
27 korr 2017

REVISED BY

PUBLISHED
ISO 20816-2:2017

National adoptions

Dridhje mekanike - Vlerësimi i dridhjeve të makinës sipas matjeve në boshtet rrotulluese - Pjesa 2: Turbinat e avullit me bazë në tokë dhe gjeneratorët me fuqi më të madhe se 50 MW me shpejtësi normale pune 1 500 r/min, 1 800 r/min, 3 000 r/min dhe 3 600 r/min

60.60 Standard published

DPS/KT 114 më tepër