SSH EN 673:2011

Qelqi në ndërtim - Përcaktimi i përçueshmërisë së nxehtësisë (vlera U) - Metoda llogaritëse

Glass in building - Determination of thermal transmittance (U value) - Calculation method
5 dhj 2011

General information

60.60     5 dhj 2011

DPS

DPS/KT 129

European Norm

81.040.20  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

This European Standard specifies a calculation method to determine the thermal transmittance of glazing with flat and parallel surfaces.
This European Standard applies to uncoated glass (including glass with structured surfaces, e.g. patterned glass), coated glass and materials not transparent in the far infrared which is the case for soda lime glass products, borosilicate glass and glass ceramic. It applies also to multiple glazing comprising such glasses and/or materials. It does not apply to multiple glazing which include in the gas space sheets or foils that are far infrared transparent. The procedure specified in this European Standard determines the U value ) (thermal transmittance) in the central area of glazing.
The edge effects due to the thermal bridge through the spacer of a sealed glazing unit or through the window frame are not included. Furthermore, energy transfer due to solar radiation is not taken into account. The effects of Georgian and other bars are excluded from the scope of this European Standard.
The Standard for the calculation of the overall U value of windows, doors and shutters (see A.1) gives normative reference to the U value calculated for the glazing components according to this standard.
For the purpose of product comparison, a vertical position of the glazing is specified. In addition, U values are calculated using the same procedure for other purposes, in particular for predicting:
- heat loss through glazing;
- conduction heat gains in summer;
- condensation on glazing surfaces;
- the effect of the absorbed solar radiation in determining the solar factor (see Clause 2).
Reference should be made to [3], [4] and [5] or other European Standards dealing with heat loss calculations for the application of glazing U values determined by this standard.
A procedure for the determination of emissivity is given in EN 12898.
The rules have been made as simple as possible consistent with accuracy.

Related directives

Directives related to this standards.

89/106/EEC

Produkte ndërtimi

305/2011

Rregullorja (BE) Nr. 305/2011 e Parlamentit Evropian dhe e Këshillit e datës 9 Mars 2011 që parashtron kushtet e harmonizuara për tregtimin e produkteve të ndërtimit dhe shfuqizimin e Direktivës së Këshillit KEE/89/106

Life cycle

PREVIOUSLY

WITHDRAWN
SSH EN 673:2009

NOW

PUBLISHED
SSH EN 673:2011
60.60 Standard published
5 dhj 2011

REVISED BY

IN_DEVELOPMENT
prSSH EN 673:2024

Related project

Adopted from EN 673:2011