SSH EN 771-1:2011

Specifikim për elementët e muraturës - Pjesa 1: Elemente murature prej qeramike

Specification for masonry units - Part 1: Clay masonry units
95.99 Withdrawal of Standard   21 pri 2016

General information

95.99     21 pri 2016

DPS

DPS/KT 51

European Norm

91.100.25  

Scope

This European Standard specifies the characteristics and performance requirements for masonry units manufactured from clay for use in masonry construction (e.g. facing and rendered masonry, loadbearing or non-loadbearing masonry structures, including internal linings and partitions, for building and civil engineering).
This European Standard is intended to apply to two groups of fired-clay masonry units:
a) LD units (see 3.4 and 5.2) comprising:
1) clay masonry units with a gross dry density of less than or equal to 1 000 kg/m3 for use in protected masonry.
b) HD units (see 3.5 and 5.3) comprising:
1) all clay masonry units for use in unprotected masonry;
2) clay masonry units with a gross dry density of greater than 1 000 kg/m3 for use in protected masonry.
This European Standard includes those clay masonry units of an overall non-rectangular parallelepiped shape.
It defines the performance related to e.g. dimensional tolerances, strength, density measured according to the corresponding test methods contained in separate European Standards.
It provides for the evaluation of conformity of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not specify standard sizes for clay masonry units, nor does it specify standard work dimensions, angles and radii of specially shaped clay masonry units. This document does not include method of measurement, tolerance and range requirements for dimensions, angles and radii characteristics of specially shaped clay masonry units.
This European Standard does not cover requirements for the following: units for paving, flue liners and storey height clay masonry units and clay masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does, however, include clay masonry units for external chimney masonry.

Related directives

Directives related to this standards.

89/106/EEC

Produkte ndërtimi

Të harmonizuara
305/2011

Rregullorja (BE) Nr. 305/2011 e Parlamentit Evropian dhe e Këshillit e datës 9 Mars 2011 që parashtron kushtet e harmonizuara për tregtimin e produkteve të ndërtimit dhe shfuqizimin e Direktivës së Këshillit KEE/89/106

Të harmonizuara

Life cycle

PREVIOUSLY

Replaces
SSH EN 771-1:2003

NOW

WITHDRAWN
SSH EN 771-1:2011
95.99 Withdrawal of Standard
21 pri 2016

REVISED BY

PUBLISHED
SSH EN 771-1:2011+A1:2015

Related project

Adopted from EN 771-1:2011