SSH CEN/TS 1793-4:2004

Pajisjet e reduktimit të zhurmës së trafikut rrugor - Metoda e testimit për përcaktimin e përformancës akustike - Pjesa 4: Karakteristikat e brendshme - Vlerat në vendodhje për shpërbërjen e tingullit

Road traffic noise reducing devices - Test method for determining the acoustic performance - Part 4: Intrinsic characteristics - In situ values of sound diffraction
95.99 Withdrawal of Standard   28 tet 2015

General information

95.99     28 tet 2015

DPS

DPS/KT 12

Technical Specification

17.140.30     93.080.30  

Scope

This document describes a test method for determining the intrinsic characteristics of sound diffraction of added devices installed on the top of traffic noise reducing devices. The test method prescribes measurements of the sound pressure level at several reference points near the top edge of a noise reducing device with and without the added device installed on its top. The effectiveness of the added device is calculated as the difference between the measured values with and without the added devices, correcting for any change in height.
The test method is intended for the following applications:
· preliminary qualification, outdoors or indoors, of added devices to be installed on noise reducing devices;
· determination of sound diffraction index difference of added devices in actual use;
· comparison of design specifications with actual performance data after the completion of the construction work;
· verification of the long term performance of added devices (with a repeated application of the method).
The test method can be applied both in situ and on samples purposely built to be tested using the method described here.
Results are expressed as a function of frequency, in one-third octave bands between 100 Hz and 5 kHz. If it is not possible to get valid measurements results over the whole frequency range indicated, the results should be given in the restricted frequency range and the reasons of the restriction(s) should be clearly reported. A single-number rating is calculated from frequency data.
For indoors measurements see annex B.

Related directives

Directives related to this standards.

89/106/EEC

Produkte ndërtimi

305/2011

Rregullorja (BE) Nr. 305/2011 e Parlamentit Evropian dhe e Këshillit e datës 9 Mars 2011 që parashtron kushtet e harmonizuara për tregtimin e produkteve të ndërtimit dhe shfuqizimin e Direktivës së Këshillit KEE/89/106

Life cycle

NOW

WITHDRAWN
SSH CEN/TS 1793-4:2004
95.99 Withdrawal of Standard
28 tet 2015

REVISED BY

PUBLISHED
SSH EN 1793-4:2015

Related project

Adopted from CEN/TS 1793-4:2003

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login