DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

SSH EN 16913:2017

Ambient air - Standard method for measurement of NO3¯, SO4²¯, Cl¯, NH4+, Na+, K+, Mg²+, Ca²+ in PM2,5 as deposited on filters

May 8, 2018

General information

60.60     Jan 23, 2018

DPS

DPS/KT 230

European Norm

13.040.20  

English  

Buying

Published

Language in which you want to receive the document.

Scope

This European Standard specifies a method for the determination of the mass concentration of water soluble NO3- (nitrate), SO42- (sulphate), Cl- (chloride), NH4+ (ammonium), Na+ (sodium), K+ (potassium), Mg2+ (magnesium), Ca2+ (calcium) in PM2,5 as deposited on filters.
This European Standard describes the analytical procedures for determining anions and cations as part of the PM2,5 particulate phase, sample extraction and analysis of anions and cations by ion chromatography. Sampling onto filters will be done in accordance with EN 12341 for PM2,5.
NOTE 1 Alternatively, cations, excluding ammonium, can be analysed by inductively coupled plasma optical emission spectrometry (ICP-OES). Ammonium can also be analysed by photometry or conductometry.
This European Standard can be used for the measurements of anions and cations as required by Directive 2008/50/EC. The method does not take into account the possible losses during sampling due to evaporation.
NOTE 2 NO3-, Cl-, NH4+ are part of the volatile fraction of PM2,5, and the concentrations determined using this standard can be used as minimum values for the concentrations of these ions in PM2,5. NO3-, NH4+, Cl- are usually up to 30 % underestimated due to evaporational losses from the filter during sampling.
This European Standard may be used at rural and urban background sites and road sites that are in accordance with the siting criteria of Directive 2008/50/EC.
This European Standard is applicable to the measurement of anion/cations in PM2,5 samples corresponding to PM2,5 mass concentrations between approximately 1 μg/m3 (i.e. the limit of detection of the standard measurement method (EN 12341) expressed as its uncertainty) up to 120 μg/m3.
The validated range of the anion and cation concentrations based on the field validation measurements is presented in Table 1.
(...)
See Annex A for the statistical analysis of the field validation measurements.

Related directives

Directives related to this standards.

2008/50/EC

Directive 2008/50/EC of the European Parliament and of the Council of 21 May 2008 on ambient air quality and cleaner air for Europe

Life cycle

NOW

PUBLISHED
SSH EN 16913:2017
60.60 Standard published
Jan 23, 2018

Related project

Adopted from EN 16913:2017