SSH EN 50637:2017

Medical electrical equipment - Particular requirements for the basic safety and essential performance of medical beds for children

Mar 23, 2018

General information

60.60     Jan 22, 2018

DPS

DPS/KT 6

European Norm

11.140  

English  

Buying

Published

Language in which you want to receive the document.

Scope

201.1 Scope, object and related standards
Clause 1 of EN 60601-1:2006, Medical electrical equipment - Part 1: General requirements for basic safety and essential performance, applies, except as follows:
201.1.1 * Scope
Replacement:
This Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL BEDS, hereafter referred to as MEDICAL BEDS as defined in 201.3.218, intended for CHILDREN as defined in 201.3.207, and ADULTS with atypical anatomy (ADULTS ranging outside the definition for ADULTS in 201.3.201).
This standard applies to medical beds with nonadjustable and electrical / mechanical adjustable functions.
This Standard applies to MEDICAL BEDS with an internal length of up to 180 cm suitable to a body length of 155 cm.
NOTE 1 The limitation of 180 cm is in order to minimize the foreseeable misuse, of a parent sharing the bed with the child or that the bed will be used by an ADULT.
If a manufacturer wishes to make a bed that can be used by both a child and an ADULT, e.g. length of 180 cm or more, then it will fulfil both EN 60601-2-52 and this particular standard.
This Standard does not apply to MEDICAL BEDS intended for ADULTS as defined in 201.3.201 (covered by EN 60601-2-52).
This Standard does not apply to :
- incubators covered by EN 60601-2-19 ;
- beds for children, covered by EN 716-1 and EN 716-2 ;
- cribs and cradles covered by EN 1130 (all parts) ;
- bunk beds and high beds, covered by EN 747-1 and 747-2.
If a clause or subclause is specifically intended to be applicable to a MEDICAL BED only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to MEDICAL BEDS and to ME SYSTEMS, as relevant.
HAZARDS inherent in the intended physiological function of MEDICAL BED or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of EN 60601-1:2006.
NOTE 2 See also 4.2 of EN 60601-1:2006.
NOTE 3 Body length is measured from crown to sole.

Life cycle

NOW

PUBLISHED
SSH EN 50637:2017
60.60 Standard published
Jan 22, 2018

Related project

Adopted from EN 50637:2017