SSH EN 1948-2:2006

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 2: Extraction and clean-up of PCDDs/PCDFs

Apr 24, 2008

General information

60.60     Apr 24, 2008

DPS

DPS/KT 230

European Norm

13.040.40  

English  

Buying

Published

Language in which you want to receive the document.

Scope

This European Standard specifies the extraction and clean-up procedures of the sampled PCDDs/PCDFs. It is integral part of the complete measurement procedure. The use of the other two parts prEN 1948-1:2005 and prEN 1948-3:2005 describing sampling or identification and quantification, respectively, is necessary for the determination of the PCDDs/PCDFs.
This European Standard has been designed to measure PCDD/PCDF concentrations at about
0,1 ng I-TEQ/m3 in stationary source emissions.
This European Standard specifies both method validation and a framework of quality control requirements which shall be fulfilled by any PCDD/PCDF extraction and clean-up methods to be applied. Some methods are described in detail in Annex A as examples of proven procedures.
Each of the three sampling methods (Part 1) can be combined with the extraction and clean-up (Part 2) and the identification and quantification (Part 3) to complete the measurement procedure.
During comparison measurements of the three sampling methods on municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 these methods have been deemed comparable within the expected range of uncertainty. Validation trials were performed on the flue gas of municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 and a dust loading of from 1 mg/m3 to 15 mg/m3. Although this European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators, the practical experience shows that it can be applied for wide concentration ranges and various emission sources.
The procedure described in the three parts of prEN 1948:2005 specifies requirements which shall be met in order to measure the 17 congeners necessary to calculate the total I-TEQ (see Table A.1 of
prEN 1948-1:2005).
Besides the determination of PCDDs/PCDFs the described measurement methods are suitable for determination of other low-volatile substances, e.g. of dioxin-like PCBs (details for sampling and analyses se

Related directives

Directives related to this standards.

89/369/EEC

Prevention of air pollution from new municipal waste incineration plants

89/429/EEC

Reduction of air pollution from existing municipal waste incineration plants

94/67/EC

Incineration of hazardous waste