SSH IEC 60331-2:2018 ED2

Testet për kabllot elektrike në kushte zjarri - Integriteti i qarkut - Pjesa 2: Metoda e provës për zjarr me goditje në një temperaturë prej të paktën 830 °C për kabllot me tension nominal deri dhe duke përfshirë 0,6/1,0 kV dhe me një total diametri jo më shumë se 20 mm

Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm
7 maj 2025

General information

60.60     8 tet 2025

95.99   

DPS

DPS/KT 3

International Standard

29.060.20     29.020     13.220.40  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

IEC 60331-2:2018 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions.
This document is applicable to cables of rated voltage not exceeding 600 V/1 000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables.
It is intended for use when testing cables of not greater than 20 mm overall diameter.
Cables of larger diameter are intended to be tested using the apparatus, procedure and requirements of IEC 60331-1.
This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-2.
Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used.
Annex A provides the method of verification of the burner and control system used for the test.
Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this standard.
This second edition cancels and replaces the first edition published in 2009. It constitutes a technical revision.
The significant technical changes with respect to the previous edition are as follows:
– extension of the scope with metallic data and telecom cables and optical fibre cables, although details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallicdata and telecom cables and optical fibre cables are not given by IEC 60331-2;
– improved description of the test environment;
– mandatory use of mass flow meters/controllers as the means of controlling accurately the input flow rates of fuel and air to the burner;
– improved figure illustrating method of mounting of the sample regarding bending radius;
– improved description of the information to be included in the test report.

Life cycle

NOW

PUBLISHED
SSH IEC 60331-2:2018 ED2
60.60 Standard published
8 tet 2025

Related project

Adopted from IEC 60331-2:2018 ED2 IDENTICAL