DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

DS CEN ISO/TR 22930-2:2021

Vlerësimi i performancës së monitorëve të vazhdueshëm të ajrit - Pjesa 2: Monitorët e ajrit bazuar në teknikat e marrjes së mostrave të rrjedhjes pa akumulim (ISO/TR 22930-2:2020)

Evaluating the performance of continuous air monitors - Part 2: Air monitors based on flow-through sampling techniques without accumulation (ISO/TR 22930-2:2020)
31 tet 2023

General information

60.60     31 tet 2023

DPS

DPS/KT 230

Technical Report

13.280  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

The use of a continuous air monitor (CAM) is mainly motivated by the need to be alerted quickly and in the most accurate way possible with an acceptable false alarm rate when significant activity concentration value is exceeded, in order to take appropriate measures to reduce exposure of those involved.
The performance of this CAM does not only depend on the metrological aspect characterized by the decision threshold, the limit of detection and the measurement uncertainties but also on its dynamic capacity characterized by its response time as well as on the minimum detectable activity concentration corresponding to an acceptable false alarm rate.
The ideal performance is to have a minimum detectable activity concentration as low as possible associated with a very short response time, but unfortunately these two criteria are in opposition. It is therefore important that the CAM and the choice of the adjustment parameters and the alarm levels be in line with the radiation protection objectives.
This document describes
— the dynamic behaviour and the determination of the response time,
— the determination of the characteristic limits (decision threshold, detection limit, limits of the coverage interval), and
— a possible way to determine the minimum detectable activity concentration and the alarms setup.
Finally the annexes of this document show actual examples of CAM data which illustrate how to quantify the CAM performance by determining the response time, the characteristics limits, the minimum detectable activity concentration and the alarms setup.

Life cycle

NOW

PUBLISHED
DS CEN ISO/TR 22930-2:2021
60.60 Standard published
31 tet 2023

Related project

Adopted from CEN ISO/TR 22930-2:2021

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login