SSH EN 15269-20:2020

Zbatim i zgjeruar i rezultateve të provës për rezistencë ndaj zjarrit dhe/ose kontrollin e përhapjes së tymit nëpër dyer, grila dhe elementët e dritareve që hapen, duke përfshirë edhe elementët e materialeve të ndërtimit - Pjesa 20: Kontroll i përhapjes së tymit tymit për dyert, grilat, tendat prej pëlhure që ulen e ngrihen dhe dritaret e hapëshme

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for doors, shutters, operable fabric curtains and openable windows
7 pri 2021

General information

60.60     7 pri 2021

DPS

DPS/KT 114

Pure national standard

91.060.50     13.220.50  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

This document, which is intended to be read in conjunction with EN 15269?1, covers doors, shutters, openable windows and fabric curtains of any material and of the following types: 1. hinged and pivoted (e.g. metal, timber, framed glazed) doors and openable windows of single or double leaf (Table A.1); 2. horizontally and vertically moving steel sliding doors of single or double leaf with and without pass doors, including telescopic doorsets (Table A.2); 3. metal rolling shutters and operable fabric curtains (excluding overlapping systems) (Table A.3). The following construction products are not covered by this standard: 1. unframed glass doors and openable windows; 2. sectional doors (including stacking doors); 3. vertically and horizontally folding doors; 4. horizontally and vertically moving timber sliding doors; 5. horizontally and vertically moving framed sliding doors (metal or timber). In this document, whenever doors are mentioned, the whole range of doors, shutters, openable windows and operable fabric curtains is included or otherwise mentioned. This document prescribes the methodology for extending the application of test results obtained from test(s) conducted in accordance with EN 1634?3. Subject to the completion of the appropriate test or tests, the extended application can cover all or some of the following examples: 1. Ambient Temperature Smoke Control (S a) and Medium Temperature Smoke Control (S 200) classifications; 2. leaf/leaves; 3. wall/ceiling fixed elements; 4. glazed elements, louvres and/or vents; 5. side, transom or overpanels; 6. items of building hardware; 7. decorative finishes; 8. intumescent, smoke, draught or acoustic seals; 9. alternative supporting construction(s).

Life cycle

PREVIOUSLY

Replaces
EN 15269-20:2009

Replaces
SSH EN 15269-20:2009

NOW

PUBLISHED
SSH EN 15269-20:2020
60.60 Standard published
7 pri 2021

Related project

Adopted from EN 15269-20:2020

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login