DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

SSH EN 14726:2019

Alumin dhe lidhje të aluminit - Përcaktimi i përbërjes kimike të aluminit dhe lidhjeve të aluminit nga spektrometria e emetimit të shkëndijës optike

Aluminium and aluminium alloys - Determination of the chemical composition of aluminium and aluminium alloys by spark optical emission spectrometry
26 maj 2020

General information

60.60     20 pri 2020

DPS

DPS/KT 133

Pure national standard

77.120.10     77.040.30  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

This document describes the criteria and the procedure for analysing aluminium and aluminium alloys with spark optical emission spectrometry (S-OES). The scope of this document covers the following:

- sample preparation;
- operational guidelines for an optical emission spectrometer (including maintenance);
- traceability of the analytical results to the International System of units: mass (kg);
- assessing the uncertainty associated with each analytical result.

This document refers to simultaneous spark emission spectrometers for the analysis of solid samples.
It applies to the determination of silicon, iron, copper, manganese, magnesium, chromium, nickel, zinc, titanium, boron, gallium, vanadium, beryllium, bismuth, calcium, cadmium, cobalt, lithium, sodium, phosphorus, lead, antimony, tin, strontium and zirconium in aluminium and aluminium alloys.

Elements other than those listed above may be analysed on the condition that:

a) suitable reference materials are available; and
b) the instrument is suitably calibrated and equipped.

In the case of determining mercury, for compliance purposes an alternate method with a limit of quantification < 0,000 1 % is recommended as its detection is compromised by intense iron interference at 253,65 nm.

The test result obtained from a spark optical emission spectrometer generally concerns an amount of less than one milligram per spark spot. The result can be used to refer to the laboratory test sample, to the aluminium or aluminium alloy melt or to the cast product.

Life cycle

PREVIOUSLY

Replaces
SSH EN 14726:2008

NOW

PUBLISHED
SSH EN 14726:2019
60.60 Standard published
20 pri 2020

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login