SSH ISO 5393:2017

Vegla rrotulluese për fiksues të filetuar - Metoda e testimit të karakteristikave të funksionimit

Rotary tools for threaded fasteners - Performance test method
2 pri 2020

General information

60.60     12 shk 2020

DPS

DPS/KT 114

Pure national standard

25.140.10  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

This document specifies a laboratory performance test method for power assembly tools (referred throughout the document as “tool”) for installing threaded fasteners.

It provides a method for the measurement of torque repeatability (scatter)

- over a range of torque rates as specified in this document,
- over a range of torque adjustment as defined by the manufacturer, and
- over a number of operating cycles as defined by the manufacturer.

It provides a method for the measurement of the precision of the built-in torque measurement system for tools incorporating such a feature. See Annex E.

It gives instructions on equipment parameters, what to test for and how to evaluate and present the test data.

It is applicable to tools
- of any power source, e.g. pneumatic, hydraulic, and electric, including battery-powered,
- which apply torque in a generally continuous manner, and
- within the torque range 0,5 Nm to 2 000 Nm. Outside this range, it is acceptable to modify the test method providing that the modification is documented in the test report.

It is not applicable to
- impact or impulse wrenches,
- ratchet wrenches or wrenches with ratcheting clutches, and
- other tools which advance fasteners in discontinuous increments, overcoming static friction at each increment.

It allows a test to be performed at any test torque level; however, in order to minimize the number of test joints necessary for a wide range of test torque levels, a list of preferred test torque levels is provided in Annex A.