SSH EN 13501-2:2016

Klasifikim zjarri i materialeve të ndërtimit dhe elementëve të ndërtimit - Pjesa 2: Klasifikimi që përdor të dhënat nga provat e rezistencës ndaj zjarrit. me përjashtim të shërbimeve të ventilimit

Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
95.99 Withdrawal of Standard   27 qer 2024

General information

95.99     27 qer 2024

DPS

DPS/KT 114

European Norm

13.220.50  

Scope

This European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this European Standard."
This European Standard deals with:
a) loadbearing elements without a fire separating function:

walls;
floors;
roofs;
beams;
columns;
balconies;
walkways;
stairs.
b) loadbearing elements with a fire separating function, with or without glazing, services and fixtures:

walls;
floors;
roofs;
raised floors.
c) products and systems for protecting elements or parts of the works:

ceilings with no independent fire resistance;
fire protective coatings, claddings and screens;
d) non-loadbearing elements or parts of works, with or without glazing, services and fixtures:

partitions;
facades (curtain walls) and external walls;
ceilings with independent fire resistance;
raised floors
fire doors and shutters and their closing devices;
smoke control doors;
conveyor systems and their closures;
penetration seals;
linear gap seals;
service ducts and shafts;
chimneys.
e) wall and ceiling coverings with fire protection ability.
f) lift landing doors which are tested according to EN 81-58 are excluded from this European Standard. Lift landing doors which are tested in accordance with EN 1634-1, are classified in accordance with 7.5.5.
Relevant test methods which have been prepared for these elements are listed in Clauses 2 and 7.

Related directives

Directives related to this standards.

305/2011

Rregullorja (BE) Nr. 305/2011 e Parlamentit Evropian dhe e Këshillit e datës 9 Mars 2011 që parashtron kushtet e harmonizuara për tregtimin e produkteve të ndërtimit dhe shfuqizimin e Direktivës së Këshillit KEE/89/106