DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

SSH EN ISO 17294-2:2016

Cilësia e ujit - Aplikimi i metodës të spektrometrisë së masës me plazmë të çiftuar me induksion (ICP-MS) - Pjesa 2: Përcaktimi i elementëve të përzgjedhur duke përfshirë izotopet e uraniumit (ISO 17294-2:2016)

Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes (ISO 17294-2:2016)
24 maj 2017
95.99 Withdrawal of Standard   11 pri 2025

General information

95.99     11 pri 2025

DPS

DPS/KT 230

European Norm

13.060.50  

anglisht  

Buying

Shfuqizuar

Language in which you want to receive the document.

Scope

ISO 17294-2:2016 specifies a method for the determination of the elements aluminium, antimony, arsenic, barium, beryllium, bismuth, boron, cadmium, caesium, calcium, cerium, chromium, cobalt, copper, dysprosium, erbium, gadolinium, gallium, germanium, gold, hafnium, holmium, indium, iridium, iron, lanthanum, lead, lithium, lutetium, magnesium, manganese, mercury, molybdenum, neodymium, nickel, palladium, phosphorus, platinum, potassium, praseodymium, rubidium, rhenium, rhodium, ruthenium, samarium, scandium, selenium, silver, sodium, strontium, terbium, tellurium, thorium, thallium, thulium, tin, tungsten, uranium and its isotopes, vanadium, yttrium, ytterbium, zinc and zirconium in water (for example, drinking water, surface water, ground water, waste water and eluates).
Taking into account the specific and additionally occurring interferences, these elements can also be determined in digests of water, sludges and sediments (for example, digests of water as described in ISO 15587‑1 or ISO 15587‑2).
The working range depends on the matrix and the interferences encountered. In drinking water and relatively unpolluted waters, the limit of quantification (xLQ) lies between 0,002 µg/l and 1,0 µg/l for most elements. The working range typically covers concentrations between several pg/l and mg/l depending on the element and pre-defined requirements.
The quantification limits of most elements are affected by blank contamination and depend predominantly on the laboratory air-handling facilities available on the purity of reagents and the cleanliness of glassware.
The lower limit of quantification is higher in cases where the determination suffers from interferences (see Clause 5) or memory effects (see ISO 17294‑1:2004, 8.2).

Life cycle

PREVIOUSLY

WITHDRAWN
SSH EN ISO 17294-2:2004

NOW

WITHDRAWN
SSH EN ISO 17294-2:2016
95.99 Withdrawal of Standard
11 pri 2025

REVISED BY

PUBLISHED
SSH EN ISO 17294-2:2023

Related project

Adopted from EN ISO 17294-2:2016

Adopted from ISO 17294-2:2016