SSH EN 301 357 V1.1.1:1999

Çështjet e pajtueshmërisë Elektromagnetike dhe të spektrit të Radios (ERM); Karakteristika teknike dhe metodat e provës për pajisje audio analoge pa kordon me brez te gjerë që përdorin antena integrale që punojnë në CEPT të rekomanduar në diapazonin e frekuencave 863 MHz në 865 MHz

ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Technical characteristics and test methods for analogue cordless wideband audio devices using integral antennas operating in the CEPT recommended 863 MHz to 865 MHz frequency range
28 sht 2016

General information

60.60     27 korr 2016

DPS

DPS/KT 10

European Norm

33.100  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

The present document covers the minimum characteristics considered necessary in order to make the best use of the
available frequencies. It does not necessarily include all the characteristics that may be required by a user, nor does it
necessarily represent the optimum performance achievable.
The present document applies to wideband cordless audio and in-ear monitoring equipment operating in the CEPT
recommended band 863 MHz to 865 MHz using analogue frequency modulation. In some countries this equipment may
be used in other frequency bands as specified in their national regulations.
The present document does not apply to wideband cordless audio or in-ear monitoring systems employing digital
modulation, Time Division Multiple Access (TDMA), frequency hopping and spread spectrum or similar forms of
modulation.
EN 300 422 [8] applies to consumer radio microphones operating in the CEPT recommended band 863 MHz to 865
MHz with a maximum power level of 10mW.
Electromagnetic Compatibility (EMC) requirements are covered by ETS 300 445 [7].
The present document may be used by accredited test laboratories for type testing of the equipment. The performance of
the equipment submitted for type testing should be representative of the performance of the corresponding production
models.
The present document contains instructions for the presentation of equipment for type testing purposes.
Power limits recommended in the present document have been chosen to allow maximum simultaneous re-usage of
frequency allocations. National regulations on power output may apply up to the limits quoted in table 1.
Table 1
Equipment max effective radiated power (erp)
Wideband cordless audio 10 mW
In-ear monitoring 10 mW
In-vehicle cordless 2 mW
Personal cordless 1 mW
The types of equipment covered by the present document are as follows:
- cordless headphones;
- cordless loudspeakers;
- in-ear monitoring;
- in-vehicle cordless;
- personal cordless.

Life cycle

NOW

PUBLISHED
SSH EN 301 357 V1.1.1:1999
60.60 Standard published
27 korr 2016

Related project

Adopted from EN 301 357 V1.1.1:1999 IDENTICAL