Pajisje mjekësore elektrike - Pjesa 2-12:Kërkesa të veçanta për sigurinë bazë dhe performanca thelbësore e kujdesit të ventilatorëvete rëndësishem (ISO 80601-2-12:2011)

Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (ISO 80601-2-12:2011)
11 pri 2013
95.99 Withdrawal of Standard   31 gush 2020

General information

95.99     31 gush 2020

DPS

DPS/KT 215

European Norm

11.040.10  

anglisht  

Buying

Shfuqizuar

Language in which you want to receive the document.

Scope

ISO 80601-2-12:2011 applies to the basic safety and essential performance of a ventilator in combination with its accessories, hereafter referred to as me equipment:
intended to be attended by a professional operator for those patients who are dependent on mechanical ventilation; and
intended for use in critical care environments in a professional healthcare facility or intended for use in transport within a professional healthcare facility.
ISO 80601-2-12:2011 is also applicable to those accessories intended by their manufacturer to be connected to a breathing system, or to a ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilator.
ISO 80601-2-12:2011 is not applicable to me equipment or an me system operating in ventilation modes intended for patients who are not dependent on mechanical ventilation.
ISO 80601-2-12:2011 is not applicable to me equipment or an me system intended for those patients who are not dependent on mechanical ventilation.
If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as relevant.
ISO 80601-2-12:2011 is not applicable to continuous positive airway pressure (CPAP) me equipment, sleep apnoea therapy me equipment, home healthcare environment ventilators, ventilatory support me equipment, emergency and transport ventilators, anaesthetic ventilators, high-frequency jet ventilators (HFJVs) and high-frequency oscillatory ventilators (HFOVs). ISO 80601-2-12:2011 does not specify the requirements for me equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility.
ISO 80601-2-12:2011 does not specify the requirements for ventilators or accessories intended for anaesthetic applications which are given in ISO 80601-2-13.
ISO 80601-2-12:2011 does not specify the requirements for ventilators or accessories intended for home care ventilators for ventilator-dependent patients which are given in ISO 10651-2.
ISO 80601-2-12:2011 does not specify the requirements for ventilators or accessories intended for emergency and transport which are given in ISO 10651-3.
ISO 80601-2-12:2011 does not specify the requirements for ventilators or accessories intended for home-care ventilatory support devices which are given in ISO 10651-6.

Related directives

Directives related to this standards.

93/42/EEC

Pajisje Mjekësore

Life cycle

PREVIOUSLY

WITHDRAWN
SSH EN 794-1:1997+A2:2009

NOW

WITHDRAWN
SSH EN ISO 80601-2-12:2011
95.99 Withdrawal of Standard
31 gush 2020

REVISED BY

PUBLISHED
SSH EN ISO 80601-2-12:2020

Related project

Adopted from EN ISO 80601-2-12:2011