SSH EN 61689:2007

Ultra akustika — Sistemet e fizioterapisë — specifikimet e fushës dhe metodat e matjes në diapazon të frekuencës 0,5 MHz deri 5 MHz

Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
95.99 Withdrawal of Standard   27 maj 2016

General information

95.99     27 maj 2016

DPS

DPS/KT 6

European Norm

11.040.60  

Scope

Is applicable to ultrasonic equipment designed for physiotherapy consisting of an ultrasonic transducer generating continuous or quasi-continuous wave ultrasonic energy in the frequency range 0,5 MHz to 5 MHz. This standard only relates to ultrasonic physiotherapy equipment employing a single plane unfocused circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head. This standard specifies: - methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods; - characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment based on reference testing methods; - guidelines for safety of the ultrasonic field generated by ultrasonic physiotherapy equipment; - methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods; - acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment based on routine testing methods. Therapeutic value and methods of use of ultrasonic physiotherapy equipment are not covered by the scope of this standard. This second edition cancels and replaces the first edition published in 1996 and constitutes a technical revision. This second edition is a result of maintenance on this standard and the referenced standards IEC 61161 (2006) and IEC 62127-1. A relatively large technical change is the determination of the effective radiating area. This is now no longer based on the measurement of four areas but only on one. This change was needed to improve the accuracy of the determination of this parameter for small transducers. Be aware that this change may alter the value obtained for this and related parameters.

Life cycle

PREVIOUSLY

Replaces
SSH EN 61689:1996

NOW

WITHDRAWN
SSH EN 61689:2007
95.99 Withdrawal of Standard
27 maj 2016

REVISED BY

PUBLISHED
SSH EN 61689:2013

Related project

Adopted from EN 61689:2007

Adopted from IEC 61689 Ed. 2.0 en

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login