Publikuar
This European Standard applies to single core, crosslinked elastomer covered arc welding cables. The cables are of rated voltage U0/U 100/100 V. The cables are intended for connections between the welding power source and the electrode holder and the work piece. Two types of cable are included, with respectively Class D and Class E conductors. These conductors are more flexible than Class 6 to EN 60228, with Class E having the greater flexibility. The maximum conductor operating temperature for each of the cables in this standard is 85 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard, and gives specific current ratings and volt drop data. This EN 50525-2-81 should be read in conjunction with EN 50525-1, which specifies general requirements.
Directives related to this standards.
Direktiva 2006/95/EC e Parlamentit Europian dhe e Këshillit e 12 dhjetorit 2006 mbi harmonizimin e ligjeve të Shteteve anëtare lidhur me pajisjet elektrike të projektuara për përdorim brenda disa kufijve të tensionit të caktuar (versioni i kodifikuar)
Të harmonizuaraDirektiva e BE 2014/35 e Parlamentit Europian dhe e Këshillit e datës 26 Shkurt 2014 mbi harmonizimin e ligjeve të Shteteve Anëtare lidhur me vënien në dispozicion të tregut të pajisjeve elektrike të destinuara për përdorim brenda disa kufijve të caktuar të tensionit
Të harmonizuara
WITHDRAWN
SSH HD 22.6 S2:1995/A1:1999
WITHDRAWN
SSH HD 22.6 S2:1995/A2:2004
WITHDRAWN
SSH HD 22.6 S2:1995
WITHDRAWN
SSH HD 22.6 S2:1995/AC:1995
PUBLISHED
SSH EN 50525-2-81:2011
60.60
Standard published
17 korr 2012