DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

SSH EN 50284:1999

Kërkesa të veçanta për ndërtimin. provën dhe markimin e aparatit elektrik të pajisjes së grupit II. të kategorisë 1 G

Special requirements for construction, test and marking of electrical apparatus of equipment group II, Category 1 G
1 jan 2005
95.99 Withdrawal of Standard   14 korr 2008

General information

95.99     14 korr 2008

DPS

DPS/KT 4

European Norm

29.260.20  

anglisht  

Buying

Shfuqizuar

Language in which you want to receive the document.

Scope

This European Standard specifies the particular requirements for construction, testing and marking of electrical apparatus of equipment group II, conformity Category 1 G as defined in EN 50014:1997. Such apparatus comprises equipment designed to be capable of functioning in conformity with the operational parameters established by the manufacturer and ensuring a very high level of protection. Category 1 G apparatus is intended for use in hazardous areas, in which potentially explosive atmospheres caused by mixtures of air and gases, vapours or mists under normal atmospheric conditions (temperature = -20 °C to +60 °C, pressure = 0,8 bar to 1,1 bar) are present continuously, for long periods or frequently. This standard also applies to apparatus mounted across the boundary between hazardous and less hazardous areas where Category 1 and Category 2 equipment may normally be installed, respectively, for example in the wall of a storage vessel. This standard also makes provision for apparatus installed outside the hazardous area, but electrically connected to apparatus of Category 1 within the hazardous area (associated apparatus).This standard supplements the requirements of EN 50014 to EN 50020 and EN 50028 to adapt the level of safety provided by those standards to the very high level of risk. NOTE: In designing apparatus for operation in a potentially explosive atmosphere under conditions other than the atmospheric conditions given above, this standard may be used as a guide. However, additional testing is recommended related specifically to the intended conditions of use. This is particularly important when the types of protection Flameproof enclosure (EN 50018) and Intrinsic safety (EN 50020) are applied

Related directives

Directives related to this standards.

94/9/EC

Pajisje dhe sisteme të mbrojtjes për përdorim në atmosfera potencialisht shpërthyese (ATEX)

Të harmonizuara

Life cycle

NOW

WITHDRAWN
SSH EN 50284:1999
95.99 Withdrawal of Standard
14 korr 2008

REVISED BY

WITHDRAWN
SSH EN 60079-26:2007

Related project

Adopted from EN 50284:1999