Sistemet kabllore të shpërndarrjes për sinjalet e televizionit dhe për sinjalet zanore - Pjesa 4: Materialet pasive me bandë të gjërë që përdoren në rrjetat me kabllo koaksiale

Cable networks for television signals, sound signals and interactive services - Part 4: Passive wideband equipment for coaxial cable networks
1 jan 2007
95.99 Withdrawal of Standard   18 dhj 2012

General information

95.99     18 dhj 2012

DPS

DPS/KT 3

European Norm

33.060.40  

anglisht  

Buying

Shfuqizuar

Language in which you want to receive the document.

Scope

This standard applies to receiver leads, system outlets, splitters and subscriber taps, passive one and two port equipment comprising filters, attenuators, equalizers, galvanic isolators, power injectors, cable splices, terminating resistors and transfer points, but excluding coaxial cables. It covers the frequency range 5 MHz to 3000 MHz, identifies performance requirements for certain parameters, lays down data publication requirements for certain parameters, stipulates methods of measurements, introduces minimum requirements defining quality (Q) grade(s). There are three Q grades for taps and splitters and two Q grades for passive one and two port equipment. There is only one Q grade for system outlet and receiver lead. Different networks require the same performance and, when integrating networks, upgrading will be avoided. Practical experience has shown these types meet most of the technical requirements necessary for supplying a minimum signal quality to the subscribers. This classification shall not be considered as a requirement but as the information for users and manufacturers on the minimum quality criteria of the material required to install networks of different sizes. The system operator has to select appropriate material to meet the minimum signal quality at the subscriber's outlet and to optimize cost/performance, taking into account the size of the network and local circumstances. All requirements and published data shall be understood as guaranteed values within the specified frequency range and in well matched conditions. For passive equipment of quality grades other than mentioned above, manufacturers shall specify minimum values for: return loss, isolation, directivity, using the relevant measurement methods and the presentation of table 1

Related directives

Directives related to this standards.

2006/95/EC

Direktiva 2006/95/EC e Parlamentit Europian dhe e Këshillit e 12 dhjetorit 2006 mbi harmonizimin e ligjeve të Shteteve anëtare lidhur me pajisjet elektrike të projektuara për përdorim brenda disa kufijve të tensionit të caktuar (versioni i kodifikuar)

Të harmonizuara

Life cycle

NOW

WITHDRAWN
SSH EN 50083-4:1998
95.99 Withdrawal of Standard
18 dhj 2012

REVISED BY

PUBLISHED
SSH EN 60728-4:2008

Related project

Adopted from EN 50083-4:1998