DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

DS CEN/TS 14807:2004

Sistemet e tubacioneve plastike - Tubacionet prej lëndësh plastike të përforcuara me qelq (GRP) - të bazuara në rezinat e poliesterit të pasaturuar (UP) - Udhëzues për analizën strukturore të linjave të tubacioneve të futura në tokë GRP-UP

Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP) - Guidance for the structural analysis of buried GRP-UP pipelines
95.99 Withdrawal of Standard   23 pri 2014

General information

95.99     23 pri 2014

DPS

DPS/KT 249

Technical Specification

23.040.20     83.140.99  

Scope

This document, which is a guidance document for use with a structural analysis procedure for below ground installations, covers limits applicable to glass-reinforced thermosetting plastics (GRP) pipes used for the conveyance of liquids under pressure or gravity conditions.
This document does not specify a particular structural analysis procedure but gives guidance on the selection of a structural analysis procedure. It concludes that any established structural analysis procedure may be used provided it includes the assessment of short and long-term deflection and buckling resistance.
NOTE 1 Products complying to the applicable system standards (prEN 1796 [1] or prEN 14364 [2]), which are not subject to internal pressure, are suitable as long as the analysis shows that the long-term deflection of the installed pipes is limited to 6 %, which is the basic assumption of the system standards. Similarly products complying with the applicable system standards (prEN 1796 [1] or prEN 14364 [2]), which are subject to internal pressure, are suitable as long as the analysis shows that the initial and long-term deflection of the installed pipes does not exceed 3 %.
NOTE 2 The approach followed when preparing a structural analysis procedure in general does not depend on the nominal size(s) of the pipe(s).
NOTE 3 A suitable structural analysis procedure would normally be capable of being used for pipes operating at different temperatures provided that the corresponding temperature re-rating factors for the relevant pipe properties are applied, as specified in the referring standard(s). Nevertheless, high service temperatures may require an additional analysis of the longitudinal stresses and strains and/or a special design of the joints.
NOTE 4 Normal structural analysis procedures are intended to cover normal soil installation conditions. Pipes to be designed for installations in abnormal or unusual conditions, e.g. in quick soils or a marine sea-bed, may require special

Related directives

Directives related to this standards.

89/106/EEC

Produkte ndërtimi

305/2011

Rregullorja (BE) Nr. 305/2011 e Parlamentit Evropian dhe e Këshillit e datës 9 Mars 2011 që parashtron kushtet e harmonizuara për tregtimin e produkteve të ndërtimit dhe shfuqizimin e Direktivës së Këshillit KEE/89/106

Life cycle

NOW

WITHDRAWN
DS CEN/TS 14807:2004
95.99 Withdrawal of Standard
23 pri 2014

REVISED BY

PUBLISHED
DS CEN/TS 14807:2013

Related project

Adopted from CEN/TS 14807:2004

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login