SSH EN 14902:2005

Cilësia e ajrit të mjedisit - Metoda standarde për matjen e Pb, Cd, As dhe Ni në fraksionin PM10 të grimcave në suspensin

Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter
15 maj 2007

General information

60.60     15 maj 2007

DPS

DPS/KT 230

European Norm

13.040.20  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

This European Standard specifies a method for the determination of particulate lead (Pb), cadmium (Cd), arsenic (As) and nickel (Ni) in ambient air that can be used in the framework of the European Council Directive on Ambient Air Quality Assessment and Management [1] and the 1st [2] and 4th [3] Daughter Directives. Performance requirements with which the method has to comply are specified in this European Standard. The performance characteristics of the method were determined in comparative field validation tests carried out at four European locations (see [4]).
This European Standard specifies a method for sampling of Pb, Cd, As and Ni as part of the PM10 aerosol, microwave digestion of the samples and analysis by graphite furnace atomic absorption spectrometry or by inductively coupled plasma (quadrupole) mass spectrometry.
This European Standard is applicable for the measurement of Pb, Cd, As and Ni as part of the PM10 aerosol fraction in the concentration ranges listed in Table 1.
Table 1 - Working ranges of the method in ng/m³
From To
Pb 1 4 000
Cd 0,1 50
As 0,5 350
Ni 2 100

The actual lower limits of the working ranges depend upon the variability of the laboratory filter blank (5.3.1). The lower limits of the working ranges given in Table 1 are expected values based upon performance achieved in the field validation tests. Similarly the upper limits of the working ranges have been set arbitrarily based upon the maximum daily values measured during the field validation tests. The method can be applied to higher concentrations provided the PM10 collection characteristics of the sampler are not compromised.

Related directives

Directives related to this standards.

96/62/EC

Managimi dhe vlerësimi i cilësisë të ajrit në ambjent

1999/30/EC

Kufizimi i vlerave për dioksid sulfuri, dioksid nitrogjeni dhe okside nitrogjeni, grimca e lëndës dhe plumbi në ajrin e ambjentit