SSH EN IEC 60519-4:2022

Safety in installations for electroheating and electromagnetic processing - Part 4: Particular requirements for arc furnace installations

Jun 16, 2023

General information

60.60     Jun 16, 2023

95.99   

DPS

DPS/KT 6

European Norm

25.180.10  

English  

Buying

Published

Language in which you want to receive the document.

Scope

This part of IEC 60519 provides particular safety requirements for arc furnace installations. This document deals with the significant hazards, hazardous situations or hazardous events relevant to industrial arc furnace installations, as listed in Annex A, for normal operation and for single fault condition as well as under conditions of reasonably foreseeable misuse.
This document specifies the requirements intended to be met by the manufacturer to ensure the safety of persons and property during the complete life cycle of the equipment from design through commissioning, operation, maintenance, inspection, to decommissioning, as well as in the event of foreseeable single fault condition that can occur in the equipment.
The rated voltage of arc furnace installation can be in the range of low voltage or high voltage, details are given in 4.2.
This standard is applicable to arc furnace installations such as:
a) furnaces for direct arc heating, forming arcs between the electrode and metal such as the electric arc furnace using alternating current (EAF AC) or direct current (EAF DC), and the ladle furnace (LF);
b) furnaces for arc-resistance heating forming arcs between the electrode and the charge material or heating the charge material by the Joule effect, such as the submerged arc resistance furnace using alternating current (SAF AC), or direct current (SAF DC).
NOTE In some documents the terms smelter or electrical reduction furnace are used.
Furnace installation for unattended operation is not covered by this standard.
This document does not provide requirements for type testing.
NOTE Industrial equipment covered by this document is typically produced as a single unit or a very small number of units; such unit usually has a very high value and can cause severe harm at disintegration.
This document does not address data security and hazards arising from neglect of security.
With respect to noise of electrical an arc furnace, ISO 13578:2017, 6.1.23 applies.

Related directives

Directives related to this standards.

2014/35/EU

Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits

Life cycle

PREVIOUSLY

PUBLISHED
SSH EN 60519-4:2013

NOW

PUBLISHED
SSH EN IEC 60519-4:2022
60.60 Standard published
Jun 16, 2023

Related project

Adopted from EN IEC 60519-4:2022

Adopted from IEC 60519-4:2021