SSH IEC 60364-7-721:2017

Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans

Apr 10, 2018

General information

60.60     Feb 6, 2018

DPS

DPS/KT 6

Pure national standard

91.140.50     29.020  

English  

Buying

Published

Language in which you want to receive the document.

Scope

IEC 60364-7-721:2017(E) lays down particular requirements applying to electrical circuits and equipment intended for the use of the caravan for habitation purposes. This new edition includes the following significant technical changes with respect to the previous edition:
- a minimum height of not less than 500 mm above the base of the cylinders is now required for cables passing through the gas cylinder compartment;
- it is now required that each independent installation shall be provided with its own main isolating switch which shall disconnect all live conductors and which shall be suitably placed in a readily accessible location in the caravan.

Life cycle

PREVIOUSLY

WITHDRAWN
SSH IEC 60364-7-721:2007

NOW

PUBLISHED
SSH IEC 60364-7-721:2017
60.60 Standard published
Feb 6, 2018