SSH EN 15502-2-1:2012+A1:2016

Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW

Sep 25, 2017
95.99 Withdrawal of Standard   Aug 29, 2023

General information

95.99     Aug 29, 2023

DPS

DPS/KT 19

European Norm

27.060.30     91.140.10  

English  

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This European Standard specifies, the requirements and test methods concerning, in particular, the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as boilers.
Where the word boiler is used, it needs to be read as the boiler including its connecting ducts, ducts and terminals, if any.
This European Standard covers gas-fired central heating boilers from the types C1 up to C9 and the types B2, B3 and B5:
NOTE For further background information on appliance types see CEN/TR 1749:2014.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which may or may not give rise to condensation under certain circumstances;
f) which are declared in the installation instructions to be either a condensing boiler or a "low temperature boiler" or a standard boiler; if no declaration is given the boiler is to be considered a standard boiler;
g) which are intended to be installed either indoors or outdoors in a partially protected place;
h) which may include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit;
i) which are designed for either sealed water systems or for open water systems;
j) which are either modular boilers, or non- modular boilers.
This European Standard also covers gas-fired condensing central heating boilers from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, ).and C(11) boilers that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa.
This European Standard provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Directive, is given in Clause 11.
This European Standard does not cover all the requirements for:
k) Appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex XC);
l) Appliances using flue dampers;
m) Appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81 ,C(12) and C(13);
n) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
o) Appliances incorporating flexible plastic flue liners;
p) C(10) boilers:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min)), - ;
q) C(11) boilers that have boiler modules:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
r) Appliances intended to be connected to a (common) flue having mechanical extraction.

Related directives

Directives related to this standards.

92/42/EEC

Efficiency requirements for new hot-water boilers fired with liquid or gaseous fuels

811/2013

Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device

813/2013

Commission Regulation (EU) No 813/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for space heaters and combination heaters

Life cycle

NOW

WITHDRAWN
SSH EN 15502-2-1:2012+A1:2016
95.99 Withdrawal of Standard
Aug 29, 2023

REVISED BY

PUBLISHED
SSH EN 15502-2-1:2022

Related project

Adopted from EN 15502-2-1:2012+A1:2016