DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

SSH EN 50617-1:2015

Railway applications - Technical parameters of train detection systems for the interoperability of the trans-European railway system - Part 1: Track circuits

Nov 23, 2015

General information

60.60     Jul 29, 2015

DPS

DPS/KT 7

European Norm

29.280  

English  

Buying

Published

Language in which you want to receive the document.

Scope

This European Standard specifies the technical parameters of track circuits associated with the disturbing current emissions limits for RST in the context of interoperability defined in the form of Frequency Management. The limits for compatibility between rolling stock and track circuits currently proposed in this standard allow provision for known interference phenomena linked to traction power supply and associated protection (over voltage, short-circuit current and basic transient effects like inrush current and power cut-off). These effects are assessed using modelling tools that have been verified by the past European research project RAILCOM.
This European Standard is intended to be used to assess compliance of track circuits equipment and other forms of train detection systems using the rails as part of their detection principles, in the context of the Interoperability Directive and the associated technical specification for interoperability relating to the control-command and signalling track-side subsystems.
The European Standard describes technical parameters to consider for achieving the compatibility of the track circuit with the emissions limits defined in the frequency management for rolling stock. These parameters are structured and allocated according to their basic references as follows:
- Technical track circuit parameters
- Train based parameters
- Track based parameters
- Environmental and other parameters including EMC
Each parameter is defined by a short general description, the definition of the requirement, the relation to other standards and a procedure to show the fulfilment of the requirement as far as necessary. An overview on the safety relevance of each parameter is given in the context of this European Standard in a separate table.
NOTE The allocated bands for track circuits and emission limits for rolling stock defined in the Frequency Management are currently used as input information to define mandatory requirements to be stated in index 77 of CCS TSI. The evaluation is conducted by the European Railway Agency.
The immunity limits of the track circuits installed on non-interoperable lines, or on interoperable lines built before the publication date of this document, are not defined in this European Standard and remain the responsibility of individual infrastructure managers, NSAs and/or suppliers of train detection systems. In this case, the limits for compatibility are usually given in the infrastructure registers and/or the notified national rules.
This European Standard is applicable to track circuit installed on all traction power supply lines, including non-electrified lines. However, for track circuit intended to be installed only on non-electrified lines, some parameters may be not applicable.

Related directives

Directives related to this standards.

2008/57/EC

DIRECTIVE 2008/57/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 17 June 2008 on the interoperability of the rail system within the Community (Recast)

Harmonized

Life cycle

NOW

PUBLISHED
SSH EN 50617-1:2015
60.60 Standard published
Jul 29, 2015

REVISED BY

IN_DEVELOPMENT
prSSH EN 50617-1:2024

Related project

Adopted from EN 50617-1:2015