DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

ISO/TS 16780:2015

Water quality — Determination of polychlorinated naphthalenes (PCN) — Method using gas chromatography (GC) and mass spectrometry (MS)
14 gush 2015

General information

90.93     21 jan 2019

ISO

ISO/TC 147/SC 2

Technical Specification

13.060.50  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

ISO/TS 16780:2015 specifies a method for the determination of polychlorinated naphthalenes (PCNs), where "poly" means "mono" to "octa", in waters and waste waters [containing less than 2 g/l solid particulate material (SPM)] using high resolution gas chromatography?high resolution mass spectrometry (HRGC?HRMS).
NOTE 1 The congeners analysed by this method are listed in Table 1.
The working range of the method is 20 pg/l to 8 ng/l. The method is optimized for PCNs, but can be modified to include other coplanar compounds such as polychlorinated dioxins and furans (PCDDs/PCDFs) and dioxin-like tetra- to heptachlorinated biphenyls (dlPCBs). This method can be used to determine PCNs in other matrices (e.g. biota, sediments, air); however, additional clean-up steps and techniques can be necessary for samples with high organic loadings. Low resolution mass spectrometry (LRMS) and mass spectrometry?mass spectrometry (MS?MS) can be used.
NOTE 2 LRMS and MS?MS conditions are summarized in Annex A.
Both LRMS and MS?MS can be less selective than HRMS and there is a possibility of bias due to interfering compounds if these techniques are used.
The detection limits and quantification levels in this method are dependent on the level of interferences as well as instrumental limitations.
NOTE 3 The minimum levels (ML) in Table 4 are the levels at which the PCNs can typically be determined with no interferences present.
This method is performance based. The analyst is permitted to modify the method, e.g. to overcome interferences, provided that all performance criteria in this method are met.
NOTE 4 The requirements for establishing method validation or equivalency are given in Clause 9.

Life cycle

PREVIOUSLY

Replaces
ISO/DIS 16780

NOW

PUBLISHED
ISO/TS 16780:2015
90.93 Standard confirmed
21 jan 2019

National adoptions

Cilësia e ujit - Përcaktimi i naftaleneve të poliklorinuara (PCN) - Metoda duke përdorur gazkromatografi dhe spektrometri të masës

60.60 Standard published

DPS/KT 230 më tepër

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login