DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

ISO 19467:2017

Thermal performance of windows and doors — Determination of solar heat gain coefficient using solar simulator
27 pri 2017

General information

90.93     5 sht 2022

ISO

ISO/TC 163/SC 1

International Standard

91.060.50     91.120.10  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

ISO 19467:2017 specifies a method to measure the solar heat gain coefficient of complete windows and doors.
ISO 19467:2017 applies to windows and doors
a) with various types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity coatings, and with spaces filled with air or other gases),
b) with opaque panels,
c) with various types of frames (wood, plastic, metallic with and without thermal barrier or any combination of materials),
d) with various types of shading devices (blind, screen, film or any attachment with shading effects),
e) with various types of active solar fenestration systems [building-integrated PV systems (BIPV) or building-integrated solar thermal collectors (BIST)].
ISO 19467:2017 does not include the following:
a) shading effects of building elements (e.g. eaves, sleeve wall, etc.);
b) heat transfer caused by air leakage between indoors and outdoors;
c) ventilation of air spaces in double and coupled windows;
d) thermal bridge effects at the rebate or joint between the window or door frame and the rest of the building envelope.
ISO 19467:2017 does not apply to the following:
a) non-vertical windows;
b) curtain walls;
c) industrial, commercial and garage doors.

Life cycle

NOW

PUBLISHED
ISO 19467:2017
90.93 Standard confirmed
5 sht 2022