DPS
Drejtoria e Përgjithshme e Standardizimit
Tel/Cel: +355 4 222 62 55
E-mail: info@dps.gov.al
Adresa: Rr.: "Reshit Collaku", (pranë ILDKPKI, kati VI), Kutia Postare 98, Tiranë - Shqipëri
Main menu

IEC 61753-1:2018 ED2

Fibre optic interconnecting devices and passive components - Performance standard - Part 1: General and guidance
24 qer 2020

General information

60.60     15 gush 2018

IEC

TC 86/SC 86B

International Standard

33.180.20  

anglisht   frëngjisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

IEC 61753-1:2018 provides guidance for the drafting of performance standards for all passive fibre optic products. This document defines the tests and severities which form the performance categories or general operating service environments and identifies those tests which are considered to be product specific. Test and severity details are given in Annex A. This second edition cancels and replaces the first edition published in 2007. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) definitions updated with new products: wall outlets, wall or pole mounted boxes, splices, ODF modules, street cabinets, hardened connectors and field mountable connectors;
b) categories U and O are replaced by categories OP and OP+. No mandatory sequence in category OP+. Category OP+ contains the tests from category OP with the addition of only 4 other tests;
c) addition of Category I (Industrial);
d) temperature ranges added (with the HD suffix to the categories C, OP, OP+ and I) in case passive optical components are placed in a housing together with active electronics (HD stands for “heat dissipation”);
e) the height of category A changed from 3 m to ground level (0 m);
f) the lower level height of category G environment changed from ground level (0 m) to –1 m below ground level. Upper level remains at 3 m above ground level;
g) addition of performance tests, test severities and performance criteria for new products: Wall outlet, wall or pole mounted boxes, mechanical splices, fusion splice protectors, ODF modules, street cabinets, field mountable connectors and hardened optical connectors;
h) test severity of "Mating durability" test for connectors in categories C, OP ,OP+ and I is reduced to 200 cycles for connectors with cylindrical ferrules and 50 cycles for connectors with rectangular ferrules;
i) test severity of "Change of temperature" test for connectors and passive optical components in category I is reduced from 20 cycles to 12 cycles (harmonized with connectors and components from other categories);
j) test severity of "Flexing of strain relief" test for connectors in categories C, OP and OP+ is reduced to 50 cycles;
k) test severities of "Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures" test for all enclosures is reduced to 5 cycles;
l) test severities of "Change of temperature" test for all protective housings in categories C, A, G and S is reduced from 20 cycles to 12 cycles (harmonized with connectors and components);
m) test severities of "Resistance to solvents and contaminating fluids" test for closures in categories G and S changed – kerosene is removed, diesel oil exposure reduced to 1 h immersion and 24 h drying at room temperature;
n) sealing performance criteria of sealed closures for categories G and A are reduced to 20 kPa overpressure.
o) the change in attenuation criterion for connectors has changed from peak-to-peak into a +/- deviation from the original value of the transmitted power at the start of the test (harmonized with the change in attenuation criterion for components, splices and protective housings).
Keywords: performance standards for all passive fibre optic products
The contents of the corrigendum of May 2019 have been included in this copy.

Life cycle

PREVIOUSLY

WITHDRAWN
IEC 61753-1:2007 ED1

NOW

PUBLISHED
IEC 61753-1:2018 ED2
60.60 Standard published
15 gush 2018

CORRIGENDA / AMENDMENTS

PUBLISHED
IEC 61753-1:2018/COR1:2019 ED2

PUBLISHED
IEC 61753-1:2018/AMD1:2020 ED2

REVISED BY

IN_DEVELOPMENT
IEC 61753-1 ED3