IEC 61587-3:2006 ED1

Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets, racks and subracks
27 qer 2006

General information

99.60     6 shk 2013

IEC

TC 48/SC 48D

International Standard

31.240  

anglisht   frëngjisht  

Buying

Revised

Language in which you want to receive the document.

Scope

Specifies the tests for empty cabinets and subracks concerning electromagnetic shielding performance, in the frequency range of 30 MHz to 2 000 MHz. Ensures physical integrity and environmental performance of cabinets and subracks, taking into account the need for different levels of performance in different applications. Was developed in close relationship to IEC 61000-5-7 but with the specific focus on subracks and cabinets and the determination of performance levels at the chosen frequency range.