IEC 60730-2-12: 2025 applies to automatic electrically operated door locks
• for use in, on, or in association with equipment for household appliance and similar use, including equipment for heating, air-conditioning and similar applications;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "door locks".
NOTE 2 Throughout this document, the word "door" means "door, cover or lid". The words "door lock" means "electrically operated door lock".
• for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 1 Controls for commercial catering, heating and air-conditioning equipment.
• that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
• used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
• utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
• using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
• that have electrical circuits and control circuits which are, for example, operated by bimetals, magnet coils, memory metals, pressure elements, temperature-sensitive expansion elements or electronic elements.
NOTE 3 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
- the inherent safety of electrically operated door locks, and
- functional safety of electrically operated door locks and safety related systems,
- electrically operated door locks where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
- the operating values, operating times, and operating sequences where such are associated with equipment safety.
This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment.
This document does not
• apply to electrically operated door locks intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists;
• take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply;
• address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system.
This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
Adoption of IEC 60730-1:2022 with all of its significant changes to IEC 60730-1:2013, IEC 60730-1:2013/AMD1:2015 and IEC 60730-1:2013/AMD2:2020
PUBLISHED
IEC 60730-2-12:2015 ED3
IN_DEVELOPMENT
IEC 60730-2-12 ED4
50.20
Proof sent to secretariat or FDIS ballot initiated: 8 weeks
16 maj 2025
Vetëm seksionet informative të projekteve janë në dispozicion të publikut. Për të parë përmbajtjen e plotë, do t'ju duhet të krijoni një llogari. Nëse jeni anëtar, ju lutemi hyni në llogarinë tuaj duke klikuar në butonin "Identifikohu".