IEC 60317-62:2020 ED2

Specifications for particular types of winding wires - Part 62: Polyester glass-fibre wound, silicone resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 200
10 qer 2020

General information

60.60     10 qer 2020

IEC

TC 55

International Standard

29.060.10  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

IEC 60317-62:2020 specifies the requirements of polyester glass-fibre wound, silicone resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 200. The impregnating agent is a silicone containing resin or varnish.The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to the title of the standard to more precisely describe the construction of the wire;
- revision to Clause 1, the scope of the standard, to provide more detail of the wire construction;
- revision to 3.2.2, general winding wire requirements of the glass fibre covering.