SSH EN 1047-2:2009+A1:2013

Njësitë e ruajtjes së sigurisë (Kasetat e sigurisë) - Klasifikimi dhe metodat e provës ndaj qëndrueshmërisë nga zjari - Pjesa 2: Dhoma e të dhënave dhe kontenieri i të dhënave

Secure storage units - Classification and methods of test for resistance to fire - Part 2: Data rooms and data container
24 dhj 2013
95.99 Withdrawal of Standard   13 dhj 2019

General information

95.99     13 dhj 2019

DPS

DPS/KT 224

European Norm

13.220.40     13.310     35.020  

anglisht  

Buying

Shfuqizuar

Language in which you want to receive the document.

Scope

This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified.
Requirements are also specified for test specimens, the technical documentation of the test specimens, materials specimens, physical fittings, the correlation of test specimens with the technical documentation and the preparation for type testing as well as test procedures.
In addition, a scheme to classify data rooms and data containers from the test results is given (see Table 2).
As well as providing protection against fire, correctly installed data rooms and data containers offer protection against impacts caused by failure during fire of components and objects external to the data room or data container.
Data rooms and data containers having the same design, protection and construction features (type and thickness of construction and protective materials, rebate geometry, lockings, doors, etc.) will only be given the same protection classification as that of the test specimen if the tolerances are within the ranges specified in Table 1.
NOTE This European Standard does not regulate the use of data rooms in the meaning of the building laws of the respective countries. In the construction of data rooms, the respective national requirements should be considered.

Life cycle

PREVIOUSLY

WITHDRAWN
SSH EN 1047-2:2003

NOW

WITHDRAWN
SSH EN 1047-2:2009+A1:2013
95.99 Withdrawal of Standard
13 dhj 2019

REVISED BY

PUBLISHED
SSH EN 1047-2:2019

Related project

Adopted from EN 1047-2:2009+A1:2013