SSH EN 674:2011

Qelqi në ndërtim - Përcaktimi i i përçueshmërisë së nxehtësisë (vlera U) - Metoda e plitkës së vëshguar (pjata e nxehtë)

Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method
26 mar 2012

General information

60.60     26 mar 2012

DPS

DPS/KT 129

European Norm

81.040.20  

anglisht  

Buying

Publikuar

Language in which you want to receive the document.

Scope

This European Standard specifies a measurement method to determine the thermal transmittance of glazing with flat and parallel surfaces. Structured surfaces, e.g. patterned glass, can be considered to be flat.
This European Standard applies to multiple glazing with outer panes which are not transparent to far infrared radiation, which is the case for soda lime silicate glass products, borosilicate glass and glass ceramics. Internal elements may be far infrared transparent.
The procedure specified in this European Standard determines the U value ) (thermal transmittance) in the central area of glazing. The edge effects, due to the thermal bridge through the spacer of an insulating glass unit or through the window frame are not included. Furthermore energy transfer due to solar radiation is not taken into account.
The procedure specified in this European Standard should generally only be considered when the calculation method detailed in EN 673 is inappropriate or unsuitable.
The document for the calculation of the overall U value of windows, doors and shutters (see [3]) gives normative reference to the U value evaluated for the glazing components according to this standard.
A vertical position of the glazing is specified.
U values evaluated according to the present standard are used for product comparison as well as for other purposes, in particular for predicting:
- heat loss through glazing;
- conduction heat gains in summer;
- condensation on glazing surfaces;
- the effects of the absorbed solar radiation in determining the solar factor (see [1]).
Reference should be made to [4], [5], or other European Standards dealing with heat loss calculations for the application of glazing U values determined by this standard.
The determination of the thermal transmittance is performed for conditions which correspond to the average situation for glazing in practice.

Related directives

Directives related to this standards.

89/106/EEC

Produkte ndërtimi

305/2011

Rregullorja (BE) Nr. 305/2011 e Parlamentit Evropian dhe e Këshillit e datës 9 Mars 2011 që parashtron kushtet e harmonizuara për tregtimin e produkteve të ndërtimit dhe shfuqizimin e Direktivës së Këshillit KEE/89/106

Life cycle

PREVIOUSLY

WITHDRAWN
SSH EN 674:2009

NOW

PUBLISHED
SSH EN 674:2011
60.60 Standard published
26 mar 2012

Related project

Adopted from EN 674:2011