SSH EN 13203-3:2010

Pajisje shtëpiake që djegin gaz për prodhimin e ujit të ngrohtë në banesa i lidhur me një kolektor diellor - Pajisjet me prurje termike jo më të madhe ose të barabartë me 70 kW dhe kapacitet depozitimi uji jo më të madh ose të barabartë me 500 l - Pjesa 3: Vlerësimi i konsumimit të energjisë

Solar supported gas-fired domestic appliances producing hot water - Appliances not exceeding 70 kW heat input and 500 litres water storage capacity - Part 3: Assessment of energy consumption
95.99 Withdrawal of Standard   29 gush 2023

General information

95.99     29 gush 2023

DPS

DPS/KT 19

European Norm

91.140.65  

Scope

This European Standard is applicable to solar supported gas-fired appliances producing domestic hot water. It applies to a system marketed as single unit or a system fully specified by a manufacturer that:
- has a gas heat input not exceeding 70 kW; and
- has a hot water storage capacity not exceeding 500 l; and
- is equipped with at least one solar collector; and
- is, with regard to the solar hydraulic circuit, considered as a forced circulation system (definition according to EN ISO 9488:1999).
The appliances covered by this European Standard are described in Annex C.
This European Standard does not apply to thermo-siphon or integral collector storage systems (definitions according to EN ISO 9488:1999).
NOTE In principle, the energy consumption of thermo-siphon solar preheat systems and integral collector storage preheat systems can also be assessed on the basis of this standard. One appropriate procedure for that purpose is to calculate the temperature level of the domestic hot water withdrawn from the thermal solar system for the reference conditions defined in this standard by using the numerical system model and the thermal solar system performance parameters according to ISO 9459-5. Based on the temperature level of the hot water withdrawn from the store the energy consumption of the gas appliance should be determined. This determination can either be done by means of calculations or by performing a test according to EN 13203-2 and using instead of the cold water inlet temperature the hot water temperature withdrawn from the store.
This standard is not intended to assess the performance:
- of the solar collector(s), which should comply with EN 12975-1 and EN 12975-2; and
- thermal solar systems and components, which should comply with EN 12976-1 and EN 12976-2.
(...)

Related directives

Directives related to this standards.

90/396/EEC

Pajisjet e gazit

Life cycle

NOW

WITHDRAWN
SSH EN 13203-3:2010
95.99 Withdrawal of Standard
29 gush 2023

REVISED BY

PUBLISHED
SSH EN 13203-3:2022