SSH IEC 61643-351:2016

Components for low-voltage surge protective devices - Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT)

Jun 19, 2017

General information

60.60     Mar 9, 2017

DPS

DPS/KT 4

International Standard

33.040.99  

English  

Buying

Published

Language in which you want to receive the document.

Scope

IEC 61643-351:2016 defines test circuits and test methods for determining and verifying the SIT surge parameters. Preferred performance values for key parameters are given. Surge isolation transformers (SITs) are used for signal transformer applications with signal levels up to 400 V peak to peak. SITs are transformers, with or without an internal-winding screen, with a rated impulse withstand voltage greater than the peak voltage of the expected common-mode surge environment. SITs are applicable to components for surge protection against indirect and direct effects of lightning or other transient overvoltage. SITs are used to mitigate the onward propagation of common-mode voltage surges. This part of IEC 61643 does not cover SIT operation under differential-mode lightning surge conditions. Keywords: Surge isolation transformers (SITs)

Life cycle

NOW

PUBLISHED
SSH IEC 61643-351:2016
60.60 Standard published
Mar 9, 2017

Related project

Adopted from IEC 61643-351 Ed. 1.0 b