DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

IEC 61643-351:2016 ED1

Components for low-voltage surge protective devices - Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT)

Oct 28, 2016

General information

60.60     Oct 28, 2016

IEC

TC 37/SC 37B

International Standard

33.040.99  

English   French  

Buying

Published

Language in which you want to receive the document.

Scope

IEC 61643-351:2016 defines test circuits and test methods for determining and verifying the SIT surge parameters. Preferred performance values for key parameters are given. Surge isolation transformers (SITs) are used for signal transformer applications with signal levels up to 400 V peak to peak. SITs are transformers, with or without an internal-winding screen, with a rated impulse withstand voltage greater than the peak voltage of the expected common-mode surge environment. SITs are applicable to components for surge protection against indirect and direct effects of lightning or other transient overvoltage. SITs are used to mitigate the onward propagation of common-mode voltage surges. This part of IEC 61643 does not cover SIT operation under differential-mode lightning surge conditions. Keywords: Surge isolation transformers (SITs)

Life cycle

NOW

PUBLISHED
IEC 61643-351:2016 ED1
60.60 Standard published
Oct 28, 2016