SSH EN 16351:2021

Timber structures - Cross laminated timber - Requirements

May 31, 2022

General information

60.60     May 31, 2022

DPS

DPS/KT 175

European Norm

79.060.10  

English  

Buying

Published

Language in which you want to receive the document.

Scope

This document sets out provisions regarding the performance of characteristics of the following Types of cross laminated timber for use in buildings and bridges:
- Type 1: Straight or curved cross laminated timber comprising only timber layers but no large finger joints;
- Type 2: Straight cross laminated timber comprising only timber layers and large finger joints;
- Type 3: Straight cross laminated timber comprising timber and wood-based panel layers but no large finger joints.
This document covers cross laminated timber of all three Types of cross laminated timber:
- manufactured according to this document, which sets up provisions for:
- boundary conditions during manufacture of cross laminated timber;
- moisture content and temperature of timber to be bonded;
- production of finger joints and bonds between layers;
- to be used in service class 1 or 2 according to EN 1995-1-1;
- made of coniferous species and poplar listed in this document;
- which may be made of layers made of different species;
- bonded with phenolic or aminoplastic or moisture curing one-component polyurethane or emulsion polymer isocyanate adhesives of adhesive Type I according to the respective standard;
- made of timber laminations having a nominal width between 40 mm (including) and 300 mm (including);
- built up of at least three orthogonally bonded layers (at least two of them timber layers);
- which may have, depending on the number of layers, adjacent layers bonded parallel to the grain;
- made of timber layers which are made of strength graded timber according to EN 14081-1;
-made of timber layers having nominal thicknesses between 6 mm (including) and 47 mm (including);
- made of timber layers which may comprise edge bonds;
- having nominal overall thicknesses up to 500 mm.
Additional provisions of this document apply for straight cross laminated timber comprising only timber layers and comprising large finger joints (Type 2):
- made from cross laminated timber pieces having the same cross-section and layup;
- made from cross laminated timber pieces having nominal cross-sectional thicknesses from 51 mm (including) up to 345 mm (including) and nominal minimum thicknesses of the outer layers not less than 17 mm (including);
- made from cross laminated timber pieces solely comprising timber layers;
- made from plane cross laminated timber pieces;
- with parallel x-axes of the jointed components;
- with large finger joints having a finger length of at least 45 mm and fingers which are visible at the two narrow sides of the components;
- having large finger joints bonded with phenolic or aminoplastic or moisture curing one-component polyurethane adhesives of adhesive Type I according to the respective standard.
Additional provisions of this document apply for straight cross laminated timber comprising timber and wood-based panel layers but no large finger joints (Type 3):
- made of structural wood-based panels specified in this document;
- made of one panel per layer and;
- having thicknesses between 6 mm (including) and 45 mm (including).
This document applies to cross laminated timber untreated or treated against biological attack.
This document does not cover:
- cross laminated timber treated with fire retardants;
- cross laminated timber which is produced from re-used timber or wood-based panels comprising re-used timber.
It also lays down procedures for assessment and verification of constancy of performance (AVPC) of cross laminated timber.

Life cycle

PREVIOUSLY

WITHDRAWN
SSH EN 16351:2016

NOW

PUBLISHED
SSH EN 16351:2021
60.60 Standard published
May 31, 2022

Related project

Adopted from EN 16351:2021