Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

Dec 26, 2018

General information

60.60     Aug 1, 2018

DPS

DPS/KT 4

European Norm

29.240.10  

English  

Buying

Published

Language in which you want to receive the document.

Scope

<span style="color:red">NEW!</span>IEC 60099-8:2017 is available as <a href="https://webstore.iec.ch/publication/61995">IEC 60099-8:2017 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.</br></br>IEC 60099-8:2017 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA)) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers.  This document defines surge arresters to protect the insulator assembly from lightning-caused over-voltages only. Therefore, and since metal-oxide resistors are not permanently connected to the line, the following items are not considered for this document:

- switching impulse spark-over voltage;

- residual voltage at steep current and switching current impulse;

- thermal stability;

- long-duration current impulse withstand duty;

- power-frequency voltage versus time characteristics of an arrester;

- disconnector test;

- aging duties by power-frequency voltage.

Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc. Designs with the EGLA's external series gap installed in parallel to an insulator are not covered by this document. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:

The Lightning discharge capability test has been completely re-written and re-named to Test to verify the repetitive charge transfer rating, Qrs with lightning discharges to reflect changes introduced in IEC 60099-4 Ed.3 (2014) regarding new methods for rating the energy and charge handling capability of metal-oxide arresters. In addition to testing to evaluate the performance of the MO resistors, procedures for evaluating the performance of the EGLA series gaps have been introduced.

- Omissions from Ed. 1 of this standard have been included, notably an RIV test and a means for determining the thermal time constant of the SUV portion of the EGLA.

- Definitions for new terms have been added

- A number of NOTES in Ed. 1 have been converted to normative requirements



Keywords: externally gapped line arresters (EGLA), lightning-caused over-voltages

Life cycle

NOW

PUBLISHED
SSH EN IEC 60099-8:2018
60.60 Standard published
Aug 1, 2018

Related project

Adopted from EN IEC 60099-8:2018

Adopted from IEC 60099-8 Ed. 2.0 en