SSH EN 50303:2000

Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust

Apr 28, 2005

General information

60.60     Jan 1, 2005

DPS

DPS/KT 4

European Norm

29.260.20  

English  

Buying

Published

Language in which you want to receive the document.

Scope

1.1 This standard specifies the design, construction, testing and marking requirements for Group I, Category M1 equipment intended to remain functional in underground parts of mines, as well as those parts of surface installations of such mines endangered by firedamp and/or coal dust clouds under normal atmospheric conditions of pressures ranging from 0,8 bar to 1,1 bar and temperatures ranging from 20 °C to + 60 °C.
1.2 It applies to all electrical and non-electrical equipment capable of causing an explosion through its own potential source of ignition.
1.3 It also applies to cables, pipes and optical fibres, when such items are used to carry energy sources and form part of equipment intended to remain functional in an atmosphere endangered by firedamp and/or coal dust.
1.4 It does not apply to category M1 Miners' Caplights, which are dealt with in prEN 62013-1 (in preparation).
NOTE 1 As the energy needed to ignite a coal dust /air cloud is in excess of 600 times* that needed to ignite a firedamp /air mixture, this standard assumes that provided intrinsically safe 'ia' circuits are constructed to be safe in an explosive atmosphere of firedamp /air, then such circuits are not capable of directly igniting an explosive atmosphere of coal dust/air.
* Based on tests performed by several member state laboratories. Verified at the UK Health & Safety Laboratories, Buxton - Report by Dr P. Tolson, dated 9 August 1995 - "Ignition of coal dust/air mixtures using a modified IEC spark test apparatus".
NOTE 2 In designing equipment for operation in explosive atmospheric conditions other than those given in 1.1 above, this standard may be used as a guide. In such cases, additional testing is recommended to allow the manufacturer to be able to demonstrate that the equipment is suitable for the exceptional conditions of use.
NOTE 3 When an explosive firedamp atmosphere occurs in the underground workings of a mine, or at a surface installation, it is imperative that the ignition risk be kept to a minimum. Member State Governments may therefore prohibit the continued use of certain Category M1 equipment in an atmosphere endangered by firedamp and/or coal dust if it is not necessary for it to remain functional for the protection of workers**.
** This has its origin in clause 5.1 of the proposals to the Governments of members States adopted by the Safety and Health Commission for Mining and Other Extractive Industries (SHCMOEI) at its meeting on 29.10.1986. Document No 6374/13/82 - "Electrical apparatus and systems for use when the concentration of firedamp exceeds the statutory limit for electricity".

Related directives

Directives related to this standards.

94/9/EC

Equipment and protective systems intended for use in potentially explosive atmospheres (ATEX)

Harmonized
2014/34/EU

Directive 2014/34/EU Of The European Parliament And Of The Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres (recast)

Harmonized

Life cycle

NOW

PUBLISHED
SSH EN 50303:2000
60.60 Standard published
Jan 1, 2005

Related project

Adopted from EN 50303:2000