SSH EN 14790:2005

Stationary source emissions - Determination of the water vapour in ducts

Apr 24, 2008
95.99 Withdrawal of Standard   May 8, 2018

General information

95.99     May 8, 2018

DPS

DPS/KT 230

European Norm

11.040.40  

English  

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This European Standard describes the condensation/adsorption technique, including the sampling system, to determine the water vapour concentration in the flue gases emitting to atmosphere from ducts and stacks.
This technique is usually used all over Europe for water vapour monitoring. However to be implemented as the Standard Reference Method (SRM), the user has to demonstrate that the performance characteristics of the method are better than the performance criteria defined in this European Standard and that the overall uncertainty of the method is less than ± 20 percent of the measured value. This European Standard as the Standard Reference Method (SRM) is used for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes.
An Alternative Method to this SRM may be used provided that the user can demonstrate equivalence according to the Technical Specification CEN/TS 14793, to the satisfaction of his national accreditation body or law.
The determination of water vapour is mainly necessary for:
regulatory purposes, to express the concentration at standard conditions (on dry gas);
adjust the flow rate for isokinetic sampling, when a dry gas flow rate metering device is used.
For both applications, the quantity to be measured is the amount of water present in the gas phase (vapour), which does not include water droplets.
This European Standard is applicable in the range from 4 percent to 40 percent relative humidity and for water vapour concentration from 29 g/m3 to 250 g/m3 as a wet gas, although for a given temperature the upper limit of the method is related to the maximum pressure of water in air or in the gas.
(continued)

Related directives

Directives related to this standards.

94/67/EC

Incineration of hazardous waste

89/369/EEC

Prevention of air pollution from new municipal waste incineration plants

88/609/EEC

Limitation of emissions of certain pollutants into the air from large combustion plants

89/429/EEC

Reduction of air pollution from existing municipal waste incineration plants

Life cycle

NOW

WITHDRAWN
SSH EN 14790:2005
95.99 Withdrawal of Standard
May 8, 2018

REVISED BY

PUBLISHED
SSH EN 14790:2017

Related project

Adopted from EN 14790:2005