DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

ISO/PAS 21448:2019

Road vehicles — Safety of the intended functionality

Jan 10, 2019

General information

90.92     Jun 19, 2020

ISO

ISO/TC 22/SC 32

Publicly Available Specification

43.040.10  

English  

Buying

Published

Language in which you want to receive the document.

Scope

The absence of unreasonable risk due to hazards resulting from functional insufficiencies of the intended functionality or by reasonably foreseeable misuse by persons is referred to as the Safety Of The Intended Functionality (SOTIF). This document provides guidance on the applicable design, verification and validation measures needed to achieve the SOTIF. This document does not apply to faults covered by the ISO 26262 series or to hazards directly caused by the system technology (e.g. eye damage from a laser sensor).
This document is intended to be applied to intended functionality where proper situational awareness is critical to safety, and where that situational awareness is derived from complex sensors and processing algorithms; especially emergency intervention systems (e.g. emergency braking systems) and Advanced Driver Assistance Systems (ADAS) with levels 1 and 2 on the OICA/SAE standard J3016 automation scales. This edition of the document can be considered for higher levels of automation, however additional measures might be necessary. This document is not intended for functions of existing systems for which well-established and well-trusted design, verification and validation (V&V) measures exist at the time of publication (e.g. Dynamic Stability Control (DSC) systems, airbag, etc.). Some measures described in this document are applicable to innovative functions of such systems, if situational awareness derived from complex sensors and processing algorithms is part of the innovation.
Intended use and reasonably foreseeable misuse are considered in combination with potentially hazardous system behaviour when identifying hazardous events.
Reasonably foreseeable misuse, which could lead directly to potentially hazardous system behaviour, is also considered as a possible event that could directly trigger a SOTIF-related hazardous event.
Intentional alteration to the system operation is considered feature abuse. Feature abuse is not in scope of this document.

Life cycle

NOW

PUBLISHED
ISO/PAS 21448:2019
90.92 Standard to be revised
Jun 19, 2020

REVISED BY

IN_DEVELOPMENT
ISO/DIS 21448

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login