ISO 17554:2014

Reaction to fire tests — Mass loss measurement

Dec 15, 2014

General information

90.93     May 8, 2026

ISO

ISO/TC 92/SC 1

International Standard

13.220.50     13.220.40  

English   French  

Buying

Published

Language in which you want to receive the document.

Scope

ISO 17554:2014 specifies a small-scale method for assessing the mass loss rate of essentially flat specimens exposed in the horizontal orientation to controlled levels of radiant heating with an external igniter under well-ventilated conditions. The mass loss rate is determined by measurement of the specimen mass and is derived numerically. The time to ignition (sustained flaming) is also measured in this test. Mass loss rate can be used as an indirect measure of heat release rate for many products. However, this is not an apparatus for determining heat release rates, and the measured mass loss rates for some products are not so closely linked to their heat release rates. Such products need to be tested in accordance with ISO 5660‑1 for correct assessment of heat release.

Life cycle

PREVIOUSLY

WITHDRAWN
ISO 17554:2005

NOW

PUBLISHED
ISO 17554:2014
90.93 Standard confirmed