DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

IEC 60245-7 ED2

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables

General information

50.20     Dec 19, 2025

PRVD    Jan 30, 2026

IEC

TC 20

International Standard

29.060.20  

Scope

IEC 60245-7:2026 defines the particular requirements for heat resistant ethylene-vinyl acetate rubber insulated cables of rated voltages up to and including 450/750 V, which apply in addition to the general requirements specified in IEC 60245-1, which apply to all cables.
The tests for cables specified in the IEC 60245 series are described in IEC 63294.

IEC 60245-7:2026 includes the following significant technical changes with respect to the previous edition:
a) reference to IEC 60245-2 for the tests has been deleted and replaced by IEC 63294;
b) reference to lift cable according to IEC 60245-5 has been deleted;
c) normative references have been updated.

This document is to be used in conjunction with IEC 60245-1.

Life cycle

PREVIOUSLY

PUBLISHED
IEC 60245-7:1994 ED1

PUBLISHED
IEC 60245-7:1994/AMD1:1997 ED1

NOW

IN_DEVELOPMENT
IEC 60245-7 ED2
50.20 Proof sent to secretariat or FDIS ballot initiated: 8 weeks
Dec 19, 2025

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to create an account. If you are a member, please log in to your account by clicking on the "Log in" button.

Login