SSH EN 81-30:2025

Safety rules for the construction and installation of lifts - Lifts for the transport of goods only - Part 30: Electric and hydraulic service lifts

Mar 3, 2026

General information

60.60     Mar 3, 2026

95.99   

DPS

DPS/KT 114

European Norm

91.140.90  

English  

Buying

Published

Language in which you want to receive the document.

Scope

1.1 This document specifies the safety rules for the construction and installation of permanently installed service lifts, with traction, positive, or hydraulic drive, serving defined landing levels, having a carrier the interior of which is regarded as inaccessible to persons on account of its dimensions and means of construction, suspended by ropes or chains or jack and moving between rigid guide rails inclined not more than 15° to the vertical.
This document covers service lifts with rated load not exceeding 300 kg and not intended to transport persons.
1.2 This document does not cover:
a) service lifts with drives other than those stated in 1.1;
b) services lifts having carrier with dimensions that exceed:
1) for floor area, 1,0 m2;
2) for depth, 1,0 m;
3) for height, 1,20 m. The height is not limited if the carrier comprises several permanent compartments, each of which satisfies the above dimensions.
c) lifting appliances, such as paternosters, mines lifts, theatrical lifts, appliances with automatic caging, skips and hoists for building and public works sites, ships hoists, platforms for exploration or drilling at sea, construction and maintenance appliances;
d) safety during operations of transport, erection, repairs and dismantling of service lifts;
e) use of glass for the walls of the well, for the carrier and for the landing doors including their vision panels;
f) hydraulic service lifts where the setting of the pressure relief valve exceeds 50 MPa;
g) any form of radiation except EMC (see 4.10.1.1.3);
h) installation in potentially explosive atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.;
i) ambient temperature in the well and machinery space(s) lower than +5 °C and higher than +40 °C;
j) health and safety of animals.
However, this document can usefully be taken as a basis.
Noise and vibrations are not dealt with in this document as they are not considered a significant nor relevant hazard for the actual type of the service lift.
Fire propagation is not dealt with in this document.
1.3 The well is regarded as accessible if the opening giving access have clear dimensions of at least 0,40 m x 0,50 m, and:
a) the horizontal depth of the well is greater than 1 m, or
b) the area of the well is greater than 1 m2, or
c) the maintenance is intended to be carried out from the carrier roof or pit regardless the well dimensions.
1.4 The machinery space is regarded as accessible if:
a) the door(s)/trapdoor(s) giving access have clear dimensions of at least 0,60 m x 0,60 m, and
b) the height of the passageway is at least 1,80 m.
NOTE A door about horizontal when closed is referred to as a trapdoor.
1.5 This document covers the safety requirements for service lifts with rated speeds up to 1 m/s.
1.6 This document is not applicable to service lifts which are installed before the date of its publication as EN.

Related directives

Directives related to this standards.

2006/42/EC

Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast)

Life cycle

NOW

PUBLISHED
SSH EN 81-30:2025
60.60 Standard published
Mar 3, 2026

Related project

Adopted from EN 81-30:2025 IDENTICAL