DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania

prSSH EN 13523-3:2024

Coil coated metals - Test methods - Part 3: Colour difference and metamerism - Instrumental comparison

General information

40.20     Feb 10, 2025

40.60    May 7, 2025

DPS

DPS/KT 298

European Norm

25.220.60  

Scope

This document specifies procedures for determining the instrumental colour difference (CIELAB or ) of an organic coating on a metallic substrate compared to another one used as a reference (usually called reference) and the metamerism depending on the illuminant.
When two colour specimens have identical spectral reflectance curves, they are matching under any illuminant irrespective of its spectral characteristics. This is termed a “spectral match”. It is also possible for two colour specimens having different spectral reflectance curves to match visually under a given light source but not to match under another light source with different spectral characteristics; such matches are termed "metameric".
One quantitative description of metamerism is the so-called "metamerism index".
Information on the metamerism index is of limited value where ΔE (instrumental colour difference for a given illuminant) is > 0,5. The metamerism index is not suited for determining the absolute colour difference or colour consistency of a given specimen at change of illuminant.
The colour difference under the reference illuminant is to be measured in colour coordinates L*, a* and b*.
Excluded from this method are organic coatings producing fluorescence and/or which are multicoloured, pearlescent or metallic.
Establishing a reference as well as the magnitude of an acceptable colour difference are not covered by this method.
Two methods are given in this document:
a) instrumental colour difference measurement using a tristimulus colourimeter;
b) instrumental colour difference measurement using a spectrophotometer or equivalent.
It is advised that care is taken when measuring e.g.
- textured surfaces;
- fluorescent coatings;
- metameric coatings;
- multi-coloured, pearlescent, metallic or special colour effect coatings.

Life cycle

PREVIOUSLY

PUBLISHED
SSH EN 13523-3:2014

PUBLISHED
SSH EN 13523-15:2015

NOW

IN_DEVELOPMENT
prSSH EN 13523-3:2024
40.20 DIS ballot initiated: 12 weeks
Feb 10, 2025

Related project

Adopted from EN 13523-3:2024 IDENTICAL

Preview

Only informative sections of projects are publicly available. To view the full content, you will need to members of the committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login