Published
This document specifies the procedures to be adopted when checking transportable refillable LPG cylinders before, during and after filling.
This document is applicable to transportable refillable LPG cylinders of water capacity not exceeding 150 l and deemed to be fitted with valves designed according to EN ISO 14245 [4] and EN ISO 15995 [5].
This document does not apply to the requirements for filling LPG cylinders that are designed and equipped for filling by the user.
This document does not apply to the requirements for filling LPG containers on vehicles.
This document is applicable to the following:
— welded and brazed steel LPG cylinders with a specified minimum wall thickness (see EN 1442 and EN 12807 [1] or an equivalent standard);
— welded steel LPG cylinders without specified minimum wall thickness (see EN 14140 or an equivalent standard);
— welded aluminium LPG cylinders (see EN 13110 [2] or an equivalent standard);
— composite LPG cylinders (see EN 14427 or an equivalent standard); and
— over-moulded cylinders (OMC).
Specific requirements for the different types of cylinders are detailed in Annex A, Annex B, Annex C, Annex D and Annex G.
This document is intended to be applicable to cylinders complying with RID/ADR [6] [7] (including pi marked cylinders) and also to existing non RID/ADR cylinder populations.
Directives related to this standards.
Directive 2008/68/EC of the European Parliament and of the council of 24 September 2008 on the inland transport of the dangerous goods
WITHDRAWN
SSH EN 1439:2017
PUBLISHED
SSH EN 1439:2021
60.60
Standard published
Aug 29, 2023